Call Us Today! +92 333 427 5008 | +92-42-35954850 | buildingstandards@hotmail.com | Download Brochure | Login Register |

NON-DESTRUCTIVE TESTING (NDT) FOR DAMAGE ASSESSMENT OF OLD MASONRY STRUCTURES.

NON-DESTRUCTIVE TESTING (NDT) FOR DAMAGE ASSESSMENT OF OLD MASONRY STRUCTURES.


NON-DESTRUCTIVE TESTING (NDT) FOR DAMAGE ASSESSMENT OF OLD MASONRY STRUCTURES.

BSL offers limited non-destructive testing NDT techniques to accurately assess the in-place conditions of historic masonry structures and heritage sites. Non-destructive techniques do not disrupt the materials used in the construction for the archeological sites additionally the historic materials are not destroyed. Currently, the following NDT services are available:

Rebound Hammer Test:

Rebound hammer test is a method used to determine the variation in the uniformity of masonry structures. It can also be used to evaluate the quality of repair works.

Ultrasonic Velocity Testing:

Ultrasonic velocity testing is a method used to determine the durability or repair works relative to the sample and subsequent measurements taken at the test locations. The test can also provide the anisotropy value of angular finishes in the rehabilitation works of high-value architectural artifacts.

In-situ Bond Strength Test:

In-situ bond strength test is employed to assess mortar bond strength. ASTM C-1072 is employed for measurement of masonry bond strength and determination of flexural bond strength. Further tests for as-built conditions engineering properties, and quality controls can be designed as per specific requirements by the client. Such test methods include measurement of in-situ compressive strength, In-Situ Measurements of masonry mortar joint and masonry deformability properties by using flat jack test. Infrared Thermography and Tomographic Imaging services can be arranged by BSL in collaboration with our foreign engineering experts.

20,000+ PROJECTS

Building Standards Limited is a consultant engineering firm registered with PEC committed to offering top-level quality, value addition, high-tech legally compliant work of structural analysis, Destructive and Non-Destructive Testing(NDT).
LIST OF THE ROOFTOP SOLAR SYSTEM INSTALLATION PROJECTS

Structural Evaluation for Adequacy of RCC Roof to withstand the Proposed Solar Panels System Load on Different Buildings in Akzonobel Pakistan Ltd.

Structural Evaluation for Adequacy of Existing PEB Structure to withstand the Solar Panels System on Production Hall Building Roof in Tetra Pak, Sundar Industrial Estate , Lahore.

Structural Evaluation Testing for Installation of Solar Panels over Reliance Cotton Spinning Mills Limited at 1-km, Warburton Road, Ferozewatton, Sheikhupura.

Report for Structural Evaluation Tests for Adequacy of RCC Roof Structure to withstand the Proposed Solar Panels System Load on Canteen Building in Pakistan Tobacco Company at Jhelum.

Report for Structural Evaluation Tests for Adequacy of RCC Roof Structure to withstand the Proposed Solar Panels System Load on Different Buildings in Pakistan Tobacco Company at Jhelum.

Report for Structural Evaluation Tests for Adequacy of RCC Roof Structure to withstand the Proposed Solar Panels System Load on Different Buildings in Pakistan Tobacco Company at Nowshera.

Report for Structural Evaluation Tests for Adequacy of RCC Roof Structure to withstand the Proposed Solar Panels System Load on GLT Plant Buildings in Pakistan Tobacco Company at Nowshera.

Structural Evaluation Testing for Installation of Solar Panels over Quaid-E-Azam Hostel Building, Sports Complex and Chemistry Lab of Government College University, Lahore.

Structural Evaluation Testing for Installation of Solar Panels over United Auto Industries (Motorbike Plant Area), Phool Nagar.

Strength Evaluation Report for Adequacy of Existing RCC Structure to withstand the Proposed Additional Loads of Solar Panels System over SNGPL Regional Office Building at Lahore.

Structural Evaluation Report for Adequacy of RCC Roof to withstand the Proposed Solar Panels System Load over SNGPL Islamabad Region Office Buildings at, Islamabad.


ROOFTOP SOLAR SYSTEM INSTALLATION PROJECTS

Card image cap

ROOFTOP SOLAR SYSTEM INSTALLATION

BSL perform structural evaluation for the installation of solar panels over roof tops of existing structures. Our expert engineers can calculate the strength of the existing roofs to withstand the expected loads of solar panels and provide cost-effective designs to install solar panel plates/assembly over different types of roof structures like RCC slab, Shell roof, Precast Roof Structure, and PEB structures.

All Projects

Card image cap

GEOTECHNICAL INVESTIGATION

10 day
Card image cap

QUALITY ASSURANCE

10 day
Card image cap

EVALUATION AND INSPECTION

10 day
Card image cap

FIRE DAMAGE MATERIAL TESTING LABORATORY

10 day
Card image cap

STRUCTURAL STABILITY

10 day
Card image cap

CRACK ANALYSIS

10 day
Card image cap

FERRO SCANNING OF STEEL REINFORCEMENT DETAIL

10 day
Card image cap

NON-DESTRUCTIVE - NDT

10 day
Card image cap

DESTRUCTIVE - DT

10 day
Card image cap

CAPO TEST

10 day
Card image cap

FIRE DAMAGED BUILDING ANALYSIS

10 day
Card image cap

LOAD TEST

10 day
Card image cap

ROOFTOP SOLAR SYSTEM INSTALLATION

10 day
Copyright Building Standards Limited All Rights Reserved
  WhatsApp